Star 6 kW | Star 8 kW | Star 10 kW | Star 12 kW | Star 15 kW | Star 17 kW | |
---|---|---|---|---|---|---|
Measurements H x W x D [mm] Height without feet | 1475 x 600 x 620 | 1475 x 600 x 620 | 1475 x 600 x 620 | 1475 x 600 x 620 | 1475 x 600 x 620 | 1475 x 600 x 620 |
Weight [kg] | 170 | 180 | 185 | 190 | 200 | 205 |
HVAC no | 5360113 | 5360100 | 5360101 | 5360102 | 5360110 | 5360111 |
Cold medium R407C [kg] | 1.8 | 2.3 | 2.5 | 2.2 | 2.4 | 2.4 |
Energy class, product 35/55 °C | A++/A++ | A++/A++ | A++/A++ | A++/A++ | A++/A++ | A++/A++ |
Energy class, system 35/55 °C | A+++/A++ | A+++/A++ | A+++/A++ | A+++/A++ | A+++/A++ | A+++/A++ |
Energy class, hot water: VLM Star 300/500 | 300:A | 300:A | 300:A | 300:A | 500:A | 500:A |
Load profile, hot water: VLM Star 300/500 | 300:XXL | 300:XXL | 300:XXL | 300:XXL | 500:XXL | 500:XXL |
Electrical connection | 400 V (3-v + 0) | 400 V (3-v + 0) | 400 V (3-v + 0) | 400 V (3-v + 0) | 400 V (3-v + 0) | 400 V (3-v + 0) |
Recommended fuse size [A], heating element 6 kW | 16 | 16 | 16 | 25 | 20 | 25 |
Recommended fuse size [A], heating element 9 kW | 20 | 25 | 25 | 25 | 35 | 35 |
Star 6 kW | Star 8 kW | Star 10 kW | Star 12 kW | Star 15 kW | Star 17 kW | |
Power output 0/35 °C * | 6.3 | 8.3 | 10.0 | 11.8 | 15.8 | 17.2 |
Power output 0/50 °C ** | 5.1 | 6.9 | 8.5 | 11.2 | 15.1 | 16.4 |
COP 0/35 °C * | 4.93 | 5.01 | 5.03 | 4.8 | 4.8 | 4.6 |
COP 0/50 °C ** | 3.46 | 3.54 | 3.39 | 3.4 | 3.4 | 3.4 |
* According to standard EN 255, inlet 0 °C / outlet +35 °C (without circulation pumps)
** According to standard EN 255, inlet 0 °C / outlet +50 °C (without circulation pumps)