The inverter compressor adapts to the heat demand
The Jämä Star Inverter ground source heat pump is equipped with a speed-controlled inverter compressor. The inverter compressor automatically adjusts to meet the power needs of the house and hot water. Thanks to the inverter compressor, optimal efficiency is achieved all year round. The result is the highest annual efficiency on the market, SCOP 5.4 (according to the EN 14825 COLD standard).
Jämä Star Inverter is connected to the Jäspi VLM Star domestic hot water tank. All connections are made on top of the equipment. This solution saves installation space and creates a stylish whole with the heat pump.
Jämä Star Inverter and Jäspi VLM Star together guarantee the customer a high hot water yield and low heating costs.
Jämä Star Inverter is also suitable to complement other forms of heating, such as oil, electric, wood, pellet or solar heating. Ask your dealer about different hybrid heating applications.
- Power class 6-12-16 kW
- The inverter compressor guarantees the greatest savings
- Excellent annual efficiency (SCOP 5,4)
- Easy to use and versatile color display
- Hot water with separate accumulator (for example Jäspi VLM Star)
- For applications with high hot water demand and / or low installation space
- MyUpway remote monitoring as standard
The inverter compressor adapts to the heat demand
The Jämä Star Inverter ground source heat pump is equipped with a speed-controlled inverter compressor. The inverter compressor automatically adjusts to meet the power needs of the house and hot water. Thanks to the inverter compressor, optimal efficiency is achieved all year round. The result is the highest annual efficiency on the market, SCOP 5.4 (according to the EN 14825 COLD standard).
Jämä Star Inverter is connected to the Jäspi VLM Star domestic hot water tank. All connections are made on top of the equipment. This solution saves installation space and creates a stylish whole with the heat pump.
Jämä Star Inverter and Jäspi VLM Star together guarantee the customer a high hot water yield and low heating costs.
Jämä Star Inverter is also suitable to complement other forms of heating, such as oil, electric, wood, pellet or solar heating. Ask your dealer about different hybrid heating applications.
- Power class 6-12-16 kW
- The inverter compressor guarantees the greatest savings
- Excellent annual efficiency (SCOP 5,4)
- Easy to use and versatile color display
- Hot water with separate accumulator (for example Jäspi VLM Star)
- For applications with high hot water demand and / or low installation space
- MyUpway remote monitoring as standard
| Star Inverter 6 kW | Star Inverter 12 kW | Star Inverter 16 kW |
Measurements H x W x D
Height without feet | 1500 x 600 x 620 mm | 1500 x 600 x 620 mm | 1500 x 600 x 620 mm |
Weight | 150 kg | 180 kg | 180 kg |
HVAC no | 5360160 | 5360161 | 5360162 |
Cold medium R407C | 1.2 kg | 2.0 kg | 2.2 kg |
Energy class, product 35/55 °C | A++/A++ | A++/A++ | A++/A++ |
Energy class, system 35/55 °C | A+++/A+++ | A+++/A+++ | A+++/A+++ |
Energy class, hot water: VLM Star 300/500 | A | A | A |
Load profile, hot water: VLM Star 300/500 | XL | XXL | XXL |
Electrical connection | 400 V 3N ~50 Hz | 400 V 3N ~50 Hz | 400 V 3N ~50 Hz |
Fuse (type C) without heating element | 16 A | 10 A | 10 A |
Heating element max. | 6.5 kW | 9 kW | 9 kW |
| Star Inverter 6 kW | Star Inverter 12 kW | Star Inverter 16 kW |
EN 14511: 2011 | | | |
Input 0/35 °C * [kW] 50 Hz | 0.67 | 1.04 | 1.83 |
Output 0/35 °C [kW] * 50 Hz | 3.15 | 5.06 | 8.89 |
COP 0/35 °C * | 4.72 | 4.87 | 4.85 |
EN 14825 | | | |
P design [kW] | 6 | 12 | 16 |
SCOP** on | 5.4 | 5.4 | 5.4 |
*At nominal power
**Cold climate, low termperature